It is designed for cooling the one CO2 glass laser tube under 150W of the laser engraving and cutting machine. (Its emitting rate is higher than 60 %.)
Cooling capacity is 800W.
Have design patent Certificate, CE and RoHS Certificate.
This water chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movable.
Features:
• It is suitable for cooling the laser tube under 150W, and the temperature can be adjusted precisely.
• You can choose different models according to local voltage and frequency.
• It can extend the using life of laser tube and ensure the engraving effect better.
• With completed water flow and over high temperature alarm functions
• It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices.
• Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal
circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement.
• CW-5000 water chiller has unique low flow alarm protection function, which ensures the cooling water cycle working safely.
• Specific disconnection alarm securing protection.
• Enclosed water tanks, water used for a long time.
• Equipped with alarm output port, can quickly protect sensitive components.
• High cost performance, low failure rate.
• Multiple power specifications; CE approval; RoHS approval.
Note: cooling water additive is forbidden by express company, so we could not put it into the package. You can buy it from local.
User-friendly control panel
The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.
Easy-to-read water level indicator
The water level indicator has 3 color areas - yellow, green and red.
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Dust-proof filter
Integrated with the grill of the side panels, easy mounting and removal.
Ease of moving and water filling
The firm handle can help move the water chillers easily.
Ventilation Distance
Alarm Function’s Description:
Flow alarm and output ports:
In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.
The cooling water circulation loop alarm causes and the work of the state table
Normal Flow
Indicator
|
Flow Alarm
Indicator
|
Buzzer |
Output Ports
Hi, H2
|
Output Ports
H1, H3
|
|
Circulating pump works properly | ON | OFF | NOT RING | DISCONNECTION | BREAKOVER |
Blocked cooling water circulation loop | OFF | ON | RING | BREAKOVER | DISCONNECTION |
Alarm of water shortage | OFF | ON | RING | BREAKOVER | DISCONNECTION |
Faulted circulating pump | OFF | ON | RING | BREAKOVER | DISCONNECTION |
Power interruption | / | / | / | BREAKOVER | DISCONNECTION |
Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.
Fill the water tank with purified water. Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine. Connect the signal line of the water tank with that of the laser machine. Please see pictures below.
B.Open the injection port to feed cooling water.
C.According to system conditions, please connect the water inlet and outlet pipe well.
D.Plug in power, turn on the power switch. (Do not start up without water in the water tank!)
E.Check the water level in the water tank.
F.Adjust parameters of temperature controller.
Maintenance
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation.
You can use non – corrosive antifreeze if you are in the northern cold regions.
Cautions
1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).
2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.
5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.
6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.
Application:
CW5000-water-chiller-cool-for-Picosecond-Lasers

CW5000-water-chiller-cool-for-UV-laser-marking-machine

CW5000-water-chiller-cool-for-Uv-solid-laser

CW5000-water-chiller-for-cooling-700W1500W-UV-light-source

CW5000-water-chiller-for-cooling-UV-LED-source


Industrial-chiller-CW-5000-for-HF-welding-machine